Performance Test for Florida II Hidropower Plant

Chile - La Florida
Linked solutions
Client Eléctrica Puntilla
Location La Florida, Talca, Región del Maule, Chile
Period 2020
Capacity 20MW

Project Description:

Performance tests for Florida II an Run-of-river hydroelectric power plant, consisting of two units of 9,66 MW each.

Services Provided

Realization of performance test required by the Chilean independent grid operator, Coordinador Eléctrico Nacional. Testing methodology according to IEC 60041.

Linked subdomains

The linked subdomains are:
Energy Efficiency Consulting Energy efficiency and integration of renewable energy