Modernisation optimises load dispatch centre in Nepal

31 Jul 2019

The load dispatch centre of the Nepal Electricity Authority no longer meets the requirements of modern grid systems. Also the control system is now outdated. Tractebel has been providing consulting services for the modernisation project from the start. 

The existing load dispatch centre in Kathmandu, operated by the Nepal Electricity Authority (NEA), was constructed in 2003 under the financial assistance of KfW. After 16 years in operation, its control system (SCADA/EMS) and related auxiliaries are now outdated. Tractebel has been providing consulting services for the modernisation project from the start.

The hardware and software components of the load dispatch centre (LDC) are obsolete and no longer meet the requirements of modern grid systems. The NEA also faces increasing difficulties with the procurement of spare parts for the reliable monitoring and control of the national transmission system. In addition, the large video display screen in the control room as well as some displays and workstations were destroyed during the heavy earthquake disaster in 2015.

An upgrade will now provide relief. The aim is to maintain the SCADA/EMS functions required for the control and monitoring of the country’s transmission system.

Early involvement of Tractebel

The project started in 2014 and Tractebel was involved from the very first pre-analysis through to the project implementation phase, with a team of planners providing all intermediate services such as the development of the conceptual design, preparation of tender documents, support in the tendering process, bid evaluation, contracting and draft approvals.

The installation work at the LDC started in April 2019 and meanwhile all the key components (SCADA hardware, large video display screen, IP telephone system and emergency power supply) are on site and installation work is almost finished. The project is now entering its “hot phase”, with the first point-to-point testing activities having been started on 6 June 2019 and now successfully completed. These precede the acceptance test and verified that all signals, such as measurements, status information and alarms/warnings, are processed by the SCADA system in the correct way. The official site acceptance test (SAT) is planned for mid-July.

The installation work for the backup control centre at the Hetauda substation started at the end of June 2019. Site testing and commissioning of the system is scheduled for autumn this year.

Point-to-point testing is used to check whether the SCADA system is working properly.

Related news

PANT01_project_image_240318

Designing a medical radioisotope production facility for cancer treatment

Jointly with its partner, MODULO architects, Tractebel will combine its infrastructure and nuclear expertise to support the design and construction of PanTera's actinium-225...

Find out more
28 Mar 2024
AdobeStock_383755906

Powering data centres with advanced nuclear technologies

Tractebel and its subsidiary company RED published a White Paper on how Small Modular Reactors (SMRs) can provide zero-emission, reliable, and sustainable energy to data...

Find out more
06 Mar 2024
Upper-Arun-photo-1

Nepal’s largest hydroelectric plant to add 1,061 MW to the national grid

Powering the future of Nepal: Plans for the monumental Upper Arun hydropower project will be set in motion in March 2024. Our experts will oversee every phase of the...

Find out more
01 Mar 2024
Thorizon_signing_website

Tractebel supports Thorizon on molten salt reactor development

Today, the Dutch-French start-up, Thorizon, and Tractebel signed a strategic three-year partnership to advance the Thorizon One molten salt reactor. Tractebel will provide...

Find out more
26 Feb 2024